The main data sheet of Terminal Strip
Main technical parameters
of Feed-through Terminal block:
(1)Outshape:
Processing of sound and
drawings of the parts fit, molding no flash, scratches,
defects such as miniature
(2) Dimension:
According to Drawing
requirement
(3) Insulation
resistance:
DC500V megger test by
Road and Road between:> MΩ charged between sites and easy
access to parts> MΩ
(4) Withstanding
Voltage:
Test voltage: Road and
Road between the site and easy to live between the contact
area AC2500V (rated voltage less than 300V, the test
voltage of 2000V), frequency 50HZ, 1 minute without
breakdown, flicker,
(5) Cable retention:
The regular insertion of
the corresponding nominal connection capacity of the
connection, plug-type terminals for 187 each root should be
able to withstand force of 78 N over the role of screw
fastening type 80N above; pluggable terminals for each root
of 250 force should be able to withstand more than the role
of 80N, screw-type fastening more than 80 N
(6) Moisture Resistance :
1. Insulation resistance:
before the test ≥ 100MΩ; test ≥ 100MΩ
2. Pressure: baseline:
AC2500V/min; test: AC2500V/min (When rated voltage less than
300V, in order to 2000V)
3. Contact resistance :
Before the test, ≤ 3mΩ; test ≤ 6mΩ, no insulation damage, no
abnormal appearance
(7) Temperature and flame
resistance:
PBT (G = 20% -30%) and
phenolic resin (Bakelite): 180 ℃ ± 3 ℃ for 2 hours, without
exception, PC temperature resistance: 180 ℃ ± 3 ℃ for 2
hours, no abnormal , PBT, Bakelite, and PC Flammability:
UL94-V0
(8) Strength test:
Products fell 6 sides
were all from a height of 30cm drop to a natural wood
surface, strength and the thickness 20mm, look no
deformation, fracture phenomenon.
(9) Contact resistance
Between the contacts and
contact resistance measurement regulations ≤ 3mΩ, durability
test ≤ 6mΩ.
(10) Logo:
Should the main body of
the terminal block has the following permanent signs:
a. Rated Voltage (V) b.
Rated current (A) c. Type d. trademarks or factory name
(11) Glow wire test:
Test, although there
should be no flame or fire but in the 30s after the removal
of the hot wire off
(12) Conductive Metal:
with high conductivity of
the brass, phosphor bronze, high elastic, nickel-plated
surface to be handled. To steel or copper alloy as the raw
material, nickel-plated surface to be handled. Conductive
parts of the surface anti-corrosion protection layer should
be smooth , no glitches, no rust and other defects.
(13) Terminal strength:
In the terminal wing to
keep the tension increases 150N 1min, terminal on the wing
can not unplug from the matrix
(14) PTI: Terminal
blocks insulated base material should be resistant to
tracking, anti-tracking index PTI175
(15) Temperature rise:
According to the rated current of power tests, the maximum
temperature in the 30K the following
(16) Heat resistance:
1. Ball pressure test:
ball indentation diameter <2mm
2. Insulation resistance:
Before the test, ≥ 100MΩ; test ≥ 100MΩ
3. Pressure: Before the
test, AC2500V/min; test AC2500V/min (as rated voltage less
than 300V, in order to 2000V)
4. Contact resistance:
Before the test, ≤ 3mΩ; test ≤ 6mΩ
5. without insulation
damage, no abnormal appearance
(17) Cold Resistance:
1. Insulation resistance:
Before the test, ≥ 100MΩ; test ≥ 100MΩ
2. Pressure: Before the
test, AC2500V/min; test AC2500V/min (When rated voltage less
than 300V, in order to 2000V)
3. Contact Resistance:
Test former ≤ 3mΩ; test ≤ 6mΩ
4. without insulation
damage, no abnormal appearance
(18) Thermal cycling test
1. Insulation resistance:
Before the test, ≥ 100MΩ; test ≥ 100MΩ
2. Pressure: Before the
test, AC2500V/min; test AC2500V/min (When rated voltage less
than 300V, in order to 2000V)
3. Contact resistance :
Before the test, ≤ 3mΩ; test ≤ 6mΩ
4. without insulation
damage, no abnormal appearance